Mitsubishi Electric repair in Belgium

Mitsubishi Electric drives, PLCs and HMIs, repaired at component level

Xania Electronics repairs Mitsubishi Electric MELSERVO servo amplifiers, FR series inverters, MELSEC PLC modules and GOT operator panels in our workshop in Mouscron, Belgium. Every unit is functionally tested before it ships back, with a case reference, a full repair report and a 1-year warranty.

Send us the model from the rating plate, such as MR-J4-…, FR-E7…, FX3U-… or GT27…, and the alarm shown on the display.

Quote
Within 5 working days, or 2 with expedite
Warranty
1 year on every repair
Return shipping
Included for Belgium and northern France

Mitsubishi Electric equipment we repair

SeriesEquipmentModels start with
MELSERVO-J2S / J3 / J4 / J5Servo amplifiersMR-J2S-…MR-J3-…MR-J4-…MR-J5-…
FR-A700 / FR-A800High-performance invertersFR-A7…FR-A8…
FR-E700 / FR-E800 / FR-D700Compact invertersFR-E7…FR-E8…FR-D7…
FR-F700 / FR-F800Fan and pump invertersFR-F7…FR-F8…
MELSEC FX / Q / L / iQ-RPLC CPUs, I/O and power supply modulesFX…Q…L…R…
GOT1000 / GOT2000Operator panelsGT1…GT2…

Your model isn’t listed? We repair at component level, so the age of a unit rarely rules it out. Send us the model and we’ll confirm.

Need a replacement instead? We can source new, refurbished or exchange units and confirm availability, condition and price, usually within one business day. Build a request for quote.

Common faults on Mitsubishi Electric units

  • Shorted power modules after a motor, cable or earth fault.
  • Worn DC bus capacitors on inverters and servo amplifiers that have run for many years.
  • Failed internal power supply: blank display, no communication.
  • Worn cooling fans, followed by heatsink overheat trips.
  • Dark screen or unresponsive touch on GOT panels.

Alarms we see often

CodeSeriesMeaning
E.OC1FR series invertersOvercurrent trip during acceleration
E.OV1FR series invertersRegenerative overvoltage during acceleration
E.THTFR series invertersInverter overload
E.FINFR series invertersHeatsink overheat
E.UVTFR series invertersUndervoltage
E.GFFR series invertersOutput side earth fault overcurrent
AL.10MR-J3, MR-J4Undervoltage
AL.20MR-J3, MR-J4Encoder communication error
AL.32MR-J3, MR-J4Overcurrent
AL.33MR-J3, MR-J4Overvoltage
AL.50MR-J3, MR-J4Overload
AL.52MR-J3, MR-J4Error excessive (following error)

An alarm shows where the unit tripped, not always what failed. If the same alarm keeps coming back after a reset, the cause can be the motor, the encoder cable or the wiring. We check for that and note it in the repair report.

Start a request for: overcurrent trips, voltage trips, overheating, a faulty GOT display or a dead unit.

How a repair works

  1. Send the unit

    Start a repair request to get your case reference, then ship the unit, at your cost, to Rue du Général Fleury 29, 7700 Mouscron with that reference written on the unit and on the box. Add the alarm code if you have it.

  2. Diagnosis and quote

    We trace the fault to the failed component and send you a fixed-price quote within 5 working days, or 2 with expedite. Nothing is repaired without your approval.

  3. Repair and test

    Failed components are replaced, then the unit is cleaned, checked and functionally tested before it leaves the workshop. Burn-in testing is available on request.

  4. Return

    The unit ships back with a full repair report and a 1-year warranty. Return shipping is included for Belgium and northern France.

How pricing works

ItemPrice
RepairFixed price per unit, parts included, quoted after diagnosis
Diagnosis when you accept the quoteIncluded in the repair price
Diagnosis when you decline the quote or the unit can’t be repairedFixed fee by type of unit, shown in the repair request form
Expedite: quote in 2 working daysOptional supplement, shown in the repair request form
Return shipping to Belgium and northern FranceIncluded

Nothing is repaired without your approval: you first receive a fixed quote for the unit. If a diagnosis needs more time, we contact you first and continue only with your approval. All prices are final, with no VAT added (small business VAT exemption). No diagnosis fee applies when the damage is obvious on arrival, for example visibly burnt components. Read the full repair conditions.

Line down and the fault only shows in the cabinet?

Some faults only appear with the real load, wiring or grounding of your installation. We can send an engineer to your site, typically within 24 to 48 hours, depending on severity and availability.

Book on-site service

Questions about Mitsubishi Electric repairs

Will my parameters or PLC program be kept?

We don’t change your parameters or your PLC program. Still, save a copy before shipping: MR Configurator2 for servo amplifiers, FR Configurator2 or the operation panel for inverters, GX Works for MELSEC PLCs and GT Designer3 for GOT panels. If settings need restoring on the machine, we can do that on site.

Can you still repair MR-J2S and FR-A500 units?

Yes. Older series still run on many machines. Repairing the existing unit avoids replacing it and changing the cabinet and the parameter set.

Do you take units from outside Belgium?

Yes. Return shipping is included for Belgium and northern France. For other destinations it is charged at cost.

Send us the model and the alarm

We’ll tell you whether we repair that unit and what happens next.

Xania Electronics, Rue du Général Fleury 29, 7700 Mouscron, Belgium
Mobile +32 470 61 37 94 · Landline +32 56 55 46 02

Xania Electronics is an independent repair service and is not affiliated with Mitsubishi Electric Corporation. Mitsubishi Electric, MELSERVO, MELSEC and GOT are trademarks of Mitsubishi Electric Corporation, used here only to identify the equipment we repair.

Share LinkedIn WhatsApp X