Yaskawa repair in Belgium

Yaskawa servo packs and inverters, repaired at component level

Xania Electronics repairs Yaskawa Sigma servo packs and AC inverters in our workshop in Mouscron, Belgium, from the older Sigma-II and Varispeed to the Sigma-7, A1000 and GA700. Every unit is functionally tested before it ships back, with a case reference, a full repair report and a 1-year warranty.

Send us the model number from the nameplate, such as SGD7S-…, SGDV-…, CIMR-… or CIPR-GA70…, and the alarm shown on the display.

Quote
Within 5 working days, or 2 with expedite
Warranty
1 year on every repair
Return shipping
Included for Belgium and northern France

Yaskawa equipment we repair

SeriesEquipmentModel numbers start with
Sigma-7Servo packsSGD7S-…SGD7W-…
Sigma-5Servo packsSGDV-…
Sigma-II / Sigma-IIIOlder servo packsSGDM-…SGDH-…SGDS-…
A1000 / V1000 / J1000AC invertersCIMR-A…CIMR-V…CIMR-J…
GA700 / GA500AC invertersCIPR-GA70…CIPR-GA50…
Varispeed G7 / F7Older AC invertersCIMR-G7…CIMR-F7…

Your model isn’t listed? We repair at component level, so the age of a unit rarely rules it out. Send us the model number and we’ll confirm.

Need a replacement instead? We can source new, refurbished or exchange units and confirm availability, condition and price, usually within one business day. Build a request for quote.

Common faults on Yaskawa units

  • Shorted IGBTs after a motor, cable or earth fault.
  • Worn DC bus capacitors on units that have run for many years.
  • Failed internal power supply: dark display or operator, no communication.
  • Worn cooling fans, followed by heatsink overtemperature trips.
  • Encoder interface faults on servo packs, often after cable damage.

Alarms we see often

CodeSeriesMeaning
A.100Sigma-5, Sigma-7Overcurrent or heatsink overheated
A.400Sigma-5, Sigma-7Overvoltage
A.410Sigma-5, Sigma-7Undervoltage
A.720Sigma-5, Sigma-7Continuous overload
A.C90Sigma-5, Sigma-7Encoder communication error
A.d00Sigma-5, Sigma-7Position error overflow
oCA1000, V1000Overcurrent
ovA1000, V1000DC bus overvoltage
Uv1A1000, V1000DC bus undervoltage
oH1A1000, V1000Heatsink overheat
GFA1000, V1000Ground fault
SCA1000, V1000Short circuit or IGBT fault

An alarm shows where the drive tripped, not always what failed. If the same alarm keeps coming back after a reset, the cause can be the motor, the encoder cable or the wiring. We check for that and note it in the repair report.

Start a request for: overcurrent trips, voltage trips, overheating or a dead unit with no power.

How a repair works

  1. Send the unit

    Start a repair request to get your case reference, then ship the unit, at your cost, to Rue du Général Fleury 29, 7700 Mouscron with that reference written on the unit and on the box. Add the alarm code if you have it.

  2. Diagnosis and quote

    We trace the fault to the failed component and send you a fixed-price quote within 5 working days, or 2 with expedite. Nothing is repaired without your approval.

  3. Repair and test

    Failed components are replaced, then the unit is cleaned, checked and functionally tested before it leaves the workshop. Burn-in testing is available on request.

  4. Return

    The unit ships back with a full repair report and a 1-year warranty. Return shipping is included for Belgium and northern France.

How pricing works

ItemPrice
RepairFixed price per unit, parts included, quoted after diagnosis
Diagnosis when you accept the quoteIncluded in the repair price
Diagnosis when you decline the quote or the unit can’t be repairedFixed fee by type of unit, shown in the repair request form
Expedite: quote in 2 working daysOptional supplement, shown in the repair request form
Return shipping to Belgium and northern FranceIncluded

Nothing is repaired without your approval: you first receive a fixed quote for the unit. If a diagnosis needs more time, we contact you first and continue only with your approval. All prices are final, with no VAT added (small business VAT exemption). No diagnosis fee applies when the damage is obvious on arrival, for example visibly burnt components. Read the full repair conditions.

Line down and the fault only shows on the machine?

Some faults only appear with the real load, the encoder cabling or the grounding of your installation. We can send an engineer to your site, typically within 24 to 48 hours, depending on severity and availability.

Book on-site service

Questions about Yaskawa repairs

Will my parameters be kept?

Save the parameters before shipping if you can: SigmaWin+ for servo packs, DriveWizard or the copy function of the digital operator for inverters. If parameters need restoring on the machine, we can do that on site.

Can you still repair Sigma-II and Varispeed units?

Yes. These older series still run on many machines. Repairing the existing unit avoids replacing the drive, the motor cabling and the parameter set.

Do you take units from outside Belgium?

Yes. Return shipping is included for Belgium and northern France. For other destinations it is charged at cost.

Send us the model number and the alarm

We’ll tell you whether we repair that unit and what happens next.

Xania Electronics, Rue du Général Fleury 29, 7700 Mouscron, Belgium
Mobile +32 470 61 37 94 · Landline +32 56 55 46 02

Xania Electronics is an independent repair service and is not affiliated with Yaskawa Electric Corporation. Yaskawa, Sigma and Varispeed are trademarks of Yaskawa Electric Corporation, used here only to identify the equipment we repair.

Share LinkedIn WhatsApp X